measurement/data_transformation-1.0.0¶
Signal transformation step.
Description
Describes the transformation between an input and output signal.
Optionally describes the associated error of the transformation step and the mathematical formula.
Outline
Schema Definitions ¶
This type is an object with the following properties:
- name
string Required No length restrictioninput_signaltag:weldx.bam.de:weldx/measurement/signal-1.0.0 Required output_signaltag:weldx.bam.de:weldx/measurement/signal-1.0.0 Required errortag:weldx.bam.de:weldx/measurement/error-1.0.0 functag:weldx.bam.de:weldx/core/mathematical_expression-1.0.0 Examples ¶
An analog (V) to digital (dimensionless) linear transformation step with a 0.01% error ratio.:
!<tag:weldx.bam.de:weldx/measurement/data_transformation-1.0.0> name: AD conversion voltage measurement input_signal: !<tag:weldx.bam.de:weldx/measurement/signal-1.0.0> signal_type: analog unit: V output_signal: !<tag:weldx.bam.de:weldx/measurement/signal-1.0.0> signal_type: digital unit: '' error: !<tag:weldx.bam.de:weldx/measurement/error-1.0.0> deviation: !unit/quantity-1.1.0 {unit: percent, value: 0.01} func: !<tag:weldx.bam.de:weldx/core/mathematical_expression-1.0.0> expression: a*x + b parameters: a: !unit/quantity-1.1.0 {unit: 1 / volt, value: 3276.8} b: !unit/quantity-1.1.0 {unit: dimensionless, value: 0.0}
Original Schema ¶
%YAML 1.1 --- $schema: "http://stsci.edu/schemas/yaml-schema/draft-01" id: "http://weldx.bam.de/schemas/weldx/measurement/data_transformation-1.0.0" tag: "tag:weldx.bam.de:weldx/measurement/data_transformation-1.0.0" title: | Signal transformation step. description: | Describes the transformation between an input and output signal. Optionally describes the associated error of the transformation step and the mathematical formula. examples: - - An analog (V) to digital (dimensionless) linear transformation step with a 0.01% error ratio. - | !<tag:weldx.bam.de:weldx/measurement/data_transformation-1.0.0> name: AD conversion voltage measurement input_signal: !<tag:weldx.bam.de:weldx/measurement/signal-1.0.0> signal_type: analog unit: V output_signal: !<tag:weldx.bam.de:weldx/measurement/signal-1.0.0> signal_type: digital unit: '' error: !<tag:weldx.bam.de:weldx/measurement/error-1.0.0> deviation: !unit/quantity-1.1.0 {unit: percent, value: 0.01} func: !<tag:weldx.bam.de:weldx/core/mathematical_expression-1.0.0> expression: a*x + b parameters: a: !unit/quantity-1.1.0 {unit: 1 / volt, value: 3276.8} b: !unit/quantity-1.1.0 {unit: dimensionless, value: 0.0} type: object properties: name: type: string input_signal: tag: "tag:weldx.bam.de:weldx/measurement/signal-1.0.0" output_signal: tag: "tag:weldx.bam.de:weldx/measurement/signal-1.0.0" error: tag: "tag:weldx.bam.de:weldx/measurement/error-1.0.0" func: tag: "tag:weldx.bam.de:weldx/core/mathematical_expression-1.0.0" required: [name, input_signal, output_signal] propertyOrder: [name, input_signal, output_signal, error, func] flowStyle: block ...
Schema documentation automatically generated by sphinx-asdf 0.1.0rc9.dev33+g0c3cae9.